Helium leak detection system for vacuum boxes in the power industry

Vacuum box leak detection system

  • Vacuum box inner cavity size: customized according to the shape and size of the workpiece to be inspected Evacuation and helium filling method: vacuum box and workpiece are evacuated and filled with helium simultaneously
  • Opening method: sliding door left and right
  • Control mode: PLC control, touch screen operation
  • Degree of automation: After manually connecting the workpieces, automatic detection can be completed
  • Safety protection: grating protection, built-in safety switch, electrical interlock, layer Level password control, etc.
  • Main configuration: all key components are imported brands

Share :

description

This equipment is suitable for dry leak detection of SF6 switch cabinets/inflatable cabinets/ring network cabinets. It adopts the method of internal inspection in a helium-filled box to reasonably control the range of pressure difference between the inside and outside of the workpiece without causing abnormal deformation of the product to be inspected. At the same time, it adopts The simultaneous use of pressure sensors and vacuum gauges greatly improves the detection safety factor.

parameters

Detection accuracy

check the accuracy

1.0×10-3—5.0×10-8Pa×m3/S

Detect beat

Detection beat

Can be set as required

Helium recovery rate

Helium recovery rate

98%

Workpiece recovery pressure

Workpiece recovery pressure

<1000Pa

Vacuum box ultimate evacuation pressure

Limit evacuation pressure of vacuum box

<10Pa

application

SF6 switch cabinet, ring network cabinet, environmentally friendly gas cabinet, column switch, load switch, power casting, etc.